6. NORMAL GAIN ADJUSTMENT
6 - 13
(c) One-touch tuning execution
POINT
For equipment in which overshoot during one-touch tuning is in the permissible
level of the in-position range, changing the value of [Pr. PA25 One-touch tuning
overshoot permissible level] will shorten the settling time and improve the
response.
When executing one-touch tuning in the amplifier command method, turn on
EM2, LSP, and LSN. When EM2, LSP, and LSN are turned off during one-touch
tuning, "C008" will be displayed at status in error code, and the one-touch tuning
will be canceled. When setting LSP and LSN to automatic on, enable the check
box "LSP, LSN auto ON" in the one-touch tuning window of MR Configurator2.
After the response mode is selected in (1) (b) in this section, clicking "Start" will start one-touch
tuning. If "Start" is clicked while the servo motor stops, "C002" or "C004" will be displayed at status
in error code. (Refer to (1) (e) in this section for error codes.)
Click "Start" with the amplifier command method selected in the servo-off, the servo-on will be
automatically enabled, and the one-touch tuning will start. In the one-touch tuning by the amplifier
command method, an optimum tuning command will be generated in the servo amplifier after servo-
on. Then, the servo motor will reciprocate, and the one-touch tuning will be executed. After the
tuning is completed or canceled, the servo amplifier will be the servo-off status. When the servo-on
command is inputted from outside, the amplifier will be the servo-on status.
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...