APPENDIX
App. - 19
App. 7 Using the neutral point of a 3-phase 400 V AC class power supply for inputting a 1-
phase 200 V AC class power supply
CAUTION
Do not input a 3-phase 400 V AC class power supply directly to the 200 V class
servo amplifier. Otherwise, it may cause a malfunction.
MC
MCCB
CNP1
Mal-
function
RA1
OFF
MC
ON
MC
SK
Emergency
stop switch
3-phase
400 V AC class
Servo amplifier
You can use the neutral point of a 3-phase 400 V AC class power supply to input a 1-phase 200 V AC class
power supply to the servo amplifier.
If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC to 240 V AC.
(1) For MR-JE-10A to MR-JE-100A
MC
MCCB
CNP1 (Note 2)
L1
L2
L3
MC
MC
SK
Do not connect anything.
Do not connect anything.
200 V AC to 240 V AC (Note 1)
Neutral
point
Emergency
stop switch
3-phase
400 V AC class
Servo amplifier
Mal-
function
RA1
OFF
ON
Note 1. If necessary, use a step-down transformer to decrease the power supply voltage to 200 V AC to
240 V AC.
2. Connect the 1-phase 200 V AC to 240 V AC power supply to L1 and L3. One of the connecting
destinations is different from MR-JE-200A servo amplifier's.
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...