8. TROUBLESHOOTING
8 - 3
No. Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Alarm
deactivation
Alarm code
Alarm
reset
Power
cycling
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
19.1 Flash-ROM error 1
DB
19
Memory error 3
(Flash-ROM)
19.2 Flash-ROM error 2
DB
0 0 0
19.4 Flash-ROM error 4
DB
19.5 Flash-ROM error 5
DB
1A
Servo motor
combination error
1A.1 Servo motor combination error 1
DB
1 1 0
1A.4 Servo motor combination error 2
DB
1E
Encoder initial
communication error 2
1E.1 Encoder
malfunction
DB
1 1 0
1F
Encoder initial
communication error 3
1F.1 Incompatible
encoder
DB
1 1 0
20.1
Encoder normal communication -
Receive data error 1
EDB
20.2
Encoder normal communication -
Receive data error 2
EDB
20.3
Encoder normal communication -
Receive data error 3
EDB
20
Encoder normal
communication error 1
20.5
Encoder normal communication -
Transmission data error 1
EDB
1 1 0
20.6
Encoder normal communication -
Transmission data error 2
EDB
20.7
Encoder normal communication -
Transmission data error 3
EDB
20.9
Encoder normal communication -
Receive data error 4
EDB
20.A
Encoder normal communication -
Receive data error 5
EDB
21
Encoder normal
communication error 2
21.1 Encoder data error 1
EDB
1 1 0
21.2 Encoder data update error
EDB
21.3 Encoder data waveform error
EDB
21.5 Encoder hardware error 1
EDB
21.6 Encoder hardware error 2
EDB
21.9 Encoder data error 2
EDB
24
Main circuit error
24.1
Ground fault detected at hardware
detection circuit
DB
1 0 0
24.2
Ground fault detected at software
detection function
DB
25
Absolute position
erased
25.1
Servo motor encoder - Absolute
position erased
DB
30.1 Regeneration heat error
DB
(Note 1)
(Note 1)
30
Regenerative error
30.2 Regeneration signal error
DB
(Note 1)
(Note 1)
0 0 1
30.3
Regeneration feedback signal
error
DB
(Note 1)
(Note 1)
31
Overspeed
31.1 Abnormal motor speed
SD
1 0 1
32.1
Overcurrent detected at hardware
detection circuit (during operation)
DB
32 Overcurrent
32.2
Overcurrent detected at software
detection function (during
operation)
DB
1 0 0
32.3
Overcurrent detected at hardware
detection circuit (during a stop)
DB
32.4
Overcurrent detected at software
detection function (during a stop)
DB
33
Overvoltage
33.1 Main circuit voltage error
EDB
0 0 1
34
SSCNET receive error
1
34.1 SSCNET receive data error
SD
34.2
SSCNET connector connection
error
SD
34.3
SSCNET communication data
error
SD
34.4 Hardware error signal detection
SD
35
Command frequency
error
35.1 Command frequency error
SD
1 0 1
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...