6. NORMAL GAIN ADJUSTMENT
6 - 19
(2) When you use push buttons
POINT
Push the "MODE" and "SET" buttons at the same time for 3 s or more to switch
to the response mode selection ("AUTO.") without going through the initial
screen of the one-touch tuning ("AUTO").
When you use push buttons, one-touch tuning can be executed in the user
command method only. Tuning cannot be executed in the amplifier command
method with the buttons.
(a) Response mode selection
Select a response mode of the one-touch tuning from 3 modes with "UP" or "DOWN". Refer to (1) (b)
in this section for a guideline of response mode.
Response mode selection display
Low mode: This mode is for low-rigid system.
Basic mode: This mode is for standard system.
High mode: This mode is for high-rigid system.
DOWN
UP