13. USING STO FUNCTION
13 - 4
13.1.6 Maintenance
This servo amplifier has alarms and warnings for maintenance that supports the Drive safety function. (Refer
to chapter 8.)
13.2 STO I/O signal connector (CN8) and signal layouts
13.2.1 Signal layouts
POINT
The pin assignment of the connectors is as viewed from the cable connector
wiring section.
TOFB2
STO2
TOFB1
STO1
STOCOM
2
CN8
STO I/O signal connector
Servo amplifier
1
4
3
6
5
8
7
TOFCOM