5. PARAMETERS
5 - 32
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PB19
VRF11
Vibration
suppression
control 1 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
value out of the range is set, the vibration suppression control will be disabled.
Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB20
VRF12
Vibration
suppression
control 1 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used.
The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a
value out of the range is set, the vibration suppression control will be disabled.
Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB21
VRF13
Vibration
suppression
control 1 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used.
Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB22
VRF14
Vibration
suppression
control 1 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is used.
Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB23
VFBF
Low-pass
filter selection
_ _ _ x Shaft resonance suppression filter selection
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "Machine resonance suppression filter 4 selection" is set to "Enabled (_ _ _ 1)"
in [Pr. PB49], the shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Summary of Contents for MR-J4-100A(-RJ)
Page 19: ...10 MEMO ...
Page 75: ...1 FUNCTIONS AND CONFIGURATION 1 56 MEMO ...
Page 83: ...2 INSTALLATION 2 8 MEMO ...
Page 159: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 203: ...4 STARTUP 4 44 MEMO ...
Page 351: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 40 MEMO ...
Page 365: ...8 TROUBLESHOOTING 8 14 MEMO ...
Page 387: ...9 DIMENSIONS 9 22 MEMO ...
Page 403: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 553: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 567: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 607: ...14 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 14 40 MEMO ...
Page 639: ...15 USING A LINEAR SERVO MOTOR 15 32 MEMO ...
Page 767: ...18 MR J4 03A6 RJ SERVO AMPLIFIER 18 84 MEMO ...
Page 856: ...APPENDIX App 41 ...
Page 905: ...MEMO ...