TROUBLESHOOTING
STEP
INSPECTION
ACTION
*13
INSPECT WIRING HARNESS BETWEEN
REFRIGERANT PRESSURE SWITCH AND A/C
AMPLIFIER FOR CONTINUITY
• Turn ignition switch to LOCK position.
• Is there continuity between A/C amplifier
connector terminal B (A/C signal) and
refrigerant pressure switch connector terminal
B?
Yes
Go to next step.
No
Repair wiring harness between refrigerant
pressure switch and A/C amplifier, then go to Step
25.
*14
INSPECT WIRING HARNESS FOR
CONTINUITY BETWEEN CLIMATE CONTROL
UNIT AND A/C AMPLIFIER
• Disconnect climate control unit
connector(16-pin).
• Is there continuity between climate control unit
connector (16-pin) terminal 2D and A/C
amplifier connector terminal C?
Yes
Go to next step.
No
Repair wiring harness between climate control
unit and A/C amplifier, then go to Step 25.
*15
CHECK TO SEE WHETHER MALFUNCTION
(SHORT TO B+) IS IN CLIMATE CONTROL
UNIT OR WIRING HARNESS (BETWEEN
CLIMATE CONTROL UNIT AND A/C
AMPLIFIER)
• Turn ignition switch to ON position.
• Test voltage at A/C amplifier connector terminal
C (A/C signal).
• Is voltage
approximately 12 V?
Yes
Repair wiring harness between climate control
unit and A/C amplifier, then go to Step 25.
No
Replace climate control unit, then go to Step 25.
*16
CHECK TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY) IS IN PCM AND
WIRING HARNESS (BETWEEN PCM AND
REFRIGERANT PRESSURE SWITCH) OR
ELSEWHERE
• Turn ignition switch to ON position.
• Test voltage at refrigerant pressure switch
connector terminal A (A/C signal) on wiring
harness side.
• Is voltage
approximately 12 V?
Yes
Go to Step 18.
No
Go to next step.
*17
CHECK TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY) IS IN PCM OR
WIRING HARNESS (BETWEEN PCM AND
REFRIGERANT PRESSURE SWITCH)
• Test voltage at PCM connector terminal 41
(A/C signal).
• Is voltage
approximately 12 V?
Yes
Repair wiring harness between PCM and
refrigerant pressure switch, then go to Step 25.
No
Inspect PCM, then go to Step 25.
18
CHECK TO SEE WHETHER MALFUNCTION IS
IN REFRIGERANT PRESSURE SWITCH OR
ELSEWHERE
• When refrigerant pressure switch connector
terminals A and B (on wiring harness side) are
shorted, does cool air blow out?
Yes
Inspect refrigerant pressure switch, then go to
Step 25.
No
Undo short, reconnect refrigerant pressure switch,
then go to next step.
19
INSPECT A/C RELAY (COIL-SIDE) POWER
SUPPLY FUSE
• Is A/C replay power supply fuse okay?
Yes
Go to next step.
No
Check for a short to ground on blown fuse’s
circuit.
Repair or replace as necessary.
Install appropriate amperage fuse
*20
INSPECT WIRING HARNESS BETWEEN FUSE
BLOCK AND A/C RELAY (COIL-SIDE) FOR
CONTINUITY
• Turn ignition switch to ON position.
• Test voltage at A/C relay connector terminal A
(IG1 signal).
• Is voltage
approximately 12 V?
Yes
Go to next step.
No
Repair wiring harness between fuse block and
A/C relay, then go to Step 25.
U -36
Summary of Contents for 626 Station Wagon
Page 25: ...CONTROL SYSTEM WIRING DIAGRAM With Immobilizer System OUTLINE F1 4 ...
Page 183: ...CONTROL SYSTEM COMPONENT LOCATION F2 7 ...
Page 204: ...MANUAL TRANSAXLE FEATURES OUTLINE J 2 OUTLINE OF CONSTRUCTION J 2 SPECIFICATIONS J 2 D J 1 ...
Page 266: ...SHIFT MECHANISM 6 Apply grease to the cam as shown K2 59 ...
Page 418: ...TROUBLESHOOTING KEYLESS ENTRY SYSTEM ON BOARD DIAGNOSTIC FUNCTION S 37 ...
Page 454: ...WARNING AND INDICATOR SYSTEM O p e ra tin g O rd e r T 32 ...