OUTLINE
S P E C I F IC A T IO N S
Item
Specification
FP, FS, FS (Hi-power)
RF Turbo
Heating capacity
(kW {kcal/h})
4.302 {3700}
5.116 {4400}
Airflow volume
(during heater operation)
Blower motor
(m3/h)
300
Electricity consumption
(during heater operation)
Blower motor
(W)
191
Cooling capacity
(kW {kcal/h})
4.244 {3650}
Airflow volume (during
air conditioner operation)
Blower motor
(m3/h)
435
Electricity consumption
(during air conditioner
operation)
Blower motor
(W)
252
Magnetic clutch
(W)
32
Condenser fan
(W)
70
80
Fan type
Blower motor
Sirocco fan
Condenser fan
Axial flow fan
Refrigerant
Type
R-134a
Regular amount
(g {oz})
625 {22.1}: condenser 26 lines
700 {24.7}: condenser 32 lines
A/C compressor
Type
Vane-rotary: H12A0
Discharge capacity
(ml {cc, fl oz})
120 {120, 4.06}
Max. allowable speed (rpm)
6,400
Lube oil
Type
ATMOS GU10
Sealed volume
(ml {cc, fl oz})
150 {150, 5.07}
Magnetic clutch clearance
(mm {in})
0.4—0.6 {0.016—0.023}
Condenser
Type
Multiflow
Radiated heat (kW {kcal/h})
6.163 {5300}: condenser 32 lines
4.826 {4150}: condenser 26 lines
Receiver/drier
Capacity
(ml {cc, fl oz})
310 {310,10.5}
Desiccant
Synthetic zeolite
Expansion valve
Type
External pressure equalizer
Evaporator
Type
Single-tank drawn cup
Refrigerant pressure
switch
Type
Dual-pressure type
Operating pressure
(MPa {kgf/cm2, psi})
0.17—0.22
3.0—3.3
{1.7—2.3, 25—32}
{30—34, 427—483}
1
i i
8
$.0,57— 113}
U l 1
0.02
0.4— 0
{0.25, 3.56} or less
{4.0—£
Thermal protector
Type
Bimetallic
Operating temperature
(°C {°F})
ON ■
t
OFF— -
113-
135—145 {275—293}
'r
-1 2 7 {236—260}
Fusible plug
Melting point
(°C {°F})
100—107 {212—224}
Temperature control
Reheat full air mix type
U -3
Summary of Contents for 626 Station Wagon
Page 25: ...CONTROL SYSTEM WIRING DIAGRAM With Immobilizer System OUTLINE F1 4 ...
Page 183: ...CONTROL SYSTEM COMPONENT LOCATION F2 7 ...
Page 204: ...MANUAL TRANSAXLE FEATURES OUTLINE J 2 OUTLINE OF CONSTRUCTION J 2 SPECIFICATIONS J 2 D J 1 ...
Page 266: ...SHIFT MECHANISM 6 Apply grease to the cam as shown K2 59 ...
Page 418: ...TROUBLESHOOTING KEYLESS ENTRY SYSTEM ON BOARD DIAGNOSTIC FUNCTION S 37 ...
Page 454: ...WARNING AND INDICATOR SYSTEM O p e ra tin g O rd e r T 32 ...