ON-BOARD DIAGNOSTIC
U–61
U
DTC 22
A6E857001038W14
Diagnostic Procedure
End Of Sie
DTC 58
A6E857001038W15
Diagnostic Procedure
End Of Sie
DTC 59
A6E857001038W16
DTC 22
Airflow mode actuator (potentiometer) system inspection
POSSIBLE
CAUSE
•
Airflow mode actuator malfunction
•
Climate control unit malfunction
•
Open circuit between airflow mode actuator and climate control unit
•
Short circuit between airflow mode actuator (terminal C) and climate control unit (terminal 1W: 24-pin)
STEP
INSPECTION
ACTION
1
•
Inspect airflow mode actuator.
•
Is it okay?
Yes
Go to next step.
No
Replace airflow mode actuator.
2
•
Disconnect climate control unit connector
(24-pin) and air mix actuator connector.
•
Is there open circuit between following
terminals of climate control unit connector
(24-pin) and airflow mode actuator
connector?
— 1B—B
— 1W—C
— 1I—A
Yes
Repair wiring harness.
No
Go to next step.
3
•
Is there short circuit to ground between
terminal 1W of climate control unit connector
(24-pin) and terminal C of airflow mode
actuator connector?
Yes
Repair wiring harness.
No
This system is normal at present. (Erase the past failure
from memory.)
DTC 58
Air mix actuator (motor lock) system inspection
POSSIBLE
CAUSE
•
Air mix actuator malfunction
•
A/C unit (air mix link and/or air mix crank) malfunction
•
Climate control unit malfunction
•
Open or short circuit between air mix actuator and climate control unit
STEP
INSPECTION
ACTION
1
•
Disconnect air mix actuator connector.
•
Connect battery positive voltage to terminal
D (or terminal F) and ground to terminal F (or
terminal D) of air mix actuator connector.
•
Does air mix actuator operate?
Yes
Connect air mix actuator connector, then go to Step 3.
No
Go to next step.
2
•
Remove air mix actuator.
•
Operate air mix link by hand.
•
Does air mix link operate smoothly?
Yes
Replace air mix actuator.
No
Replace air mix link and/or air mix crank.
3
•
Disconnect climate control unit connect (12-
pin).
•
Connect battery positive voltage to terminal
2D (or terminal 2C) and ground to terminal
2C (or terminal 2D) of climate control unit
connector (24-pin).
•
Does air mix actuator operate?
Yes
Replace climate control unit.
No
Repair wiring harness.
DTC 59
Airflow mode actuator (motor lock) system inspection
POSSIBLE
CAUSE
•
Airflow mode actuator malfunction
•
A/C unit (airflow mode links and/or airflow mode cranks) malfunction
•
Climate control unit malfunction
•
Open or short circuit between airflow mode actuator and climate control unit
Summary of Contents for 6 2002
Page 104: ...F 4 LOCATION INDEX End Of Sie FUEL SYSTEM A6E390001006W01 Engine Room Side A6E3912W015...
Page 151: ...F 36 EXHAUST SYSTEM A6E3914W002...
Page 312: ...F 182 TROUBLESHOOTING QUICK DIAGNOSTIC CHART A6E398018881W02 A6E3980W001...
Page 313: ...TROUBLESHOOTING F 183 F A6E3980W002...
Page 314: ...F 184 TROUBLESHOOTING A6E3980W003...
Page 315: ...TROUBLESHOOTING F 185 F End Of Sie A6E3980W004...
Page 410: ...K 3 K...
Page 526: ...TROUBLESHOOTING K 115 K QUICK DIAGNOSIS CHART A6E568001030W04 A6E5680W001...
Page 527: ...K 116 TROUBLESHOOTING End Of Sie A6E5680W002...
Page 653: ...ON BOARD DIAGNOSTIC ABS TCS P 57 P...
Page 701: ...TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL P 105 P Vehicle with ABS TCS A6E6980W002...
Page 819: ...OUTSIDE MIRROR S 60 2 THIS PAGE IS INTENTIONALLY LEFT BLANK End Of Sie...
Page 971: ...T 76 WARNING AND INDICATOR SYSTEM Operating Order A6E8118W009...
Page 1150: ...U 4 LOCATION INDEX End Of Sie CONTROL SYSTEM A6E850001042W01 L H D A6E8500W003 A6E8500W004...
Page 1152: ...U 6 LOCATION INDEX R H D A6E8500W005 A6E8500W006...