U–60
ON-BOARD DIAGNOSTIC
End Of Sie
DTC 19
A6E857001038W12
Diagnostic Procedure
End Of Sie
DTC 21
A6E857001038W13
Diagnostic Procedure
End Of Sie
2
•
Disconnect airflow mode actuator connector.
•
Is resistance between terminals 1U and 1I of
climate control unit connector (24-pin) more
than
387 ohms
?
Yes
Go to next step.
No
Repair wiring harness. (Short circuit)
3
•
Disconnect climate control unit connector
(24-pin).
•
Is resistance between terminals 1B and 1I of
climate control unit connector (24-pin) less
than
4.8 kilohms
?
Yes
Go to next step.
No
Repair wiring harness. (Open circuit)
4
•
Is resistance between terminals 1B and 1U
of climate control unit connector (24-pin) less
than
4.2 kilohms
?
Yes
Replace climate control unit.
No
Repair wiring harness. (Open circuit)
STEP
INSPECTION
ACTION
DTC 19
Air mix actuator (potentiometer) system inspection
POSSIBLE
CAUSE
•
Air mix actuator malfunction
•
Climate control unit malfunction
•
Open circuit between air mix actuator and climate control unit
•
Short circuit between air mix actuator (terminal C) and climate control unit (terminal 1U: 24-pin)
STEP
INSPECTION
ACTION
1
•
Inspect air mix actuator.
•
Is it okay?
Yes
Go to next step.
No
Replace air mix actuator.
2
•
Disconnect climate control unit connector
(24-pin) and air mix actuator connector.
•
Is there open circuit between following
terminals of climate control unit connector
(24-pin) and air mix actuator connector?
— 1B—B
— 1U—C
— 1I—A
Yes
Repair wiring harness.
No
Go to next step.
3
•
Is there short circuit to ground between
terminal 1U of climate control unit connector
(24-pin) and terminal C of air mix actuator
connector?
Yes
Repair wiring harness.
No
This system is normal at present. (Erase the past failure
from memory.)
DTC 21
Airflow mode actuator (potentiometer) system inspection
POSSIBLE
CAUSE
•
Airflow mode actuator malfunction
•
Climate control unit malfunction
•
Open circuit between airflow mode actuator and climate control unit
•
Short circuit between airflow mode actuator (terminal C) and climate control unit (terminal 1W: 24-pin)
STEP
INSPECTION
ACTION
1
•
Inspect airflow mode actuator.
•
Is it okay?
Yes
Go to next step.
No
Replace airflow mode actuator.
2
•
Disconnect air mix actuator connector.
•
Is resistance between terminals 1W and 1I of
climate control unit connector (24-pin) more
than
387 ohms
?
Yes
Go to next step.
No
Repair wiring harness. (Short circuit)
3
•
Disconnect climate control unit connector
(24-pin).
•
Is resistance between terminals 1B and 1I of
climate control unit connector (24-pin) less
than
4.8 kilohms
?
Yes
Go to next step.
No
Repair wiring harness. (Open circuit)
4
•
Is resistance between terminals 1B and 1W
of climate control unit connector (24-pin) less
than
4.2 kilohms
?
Yes
Replace climate control unit.
No
Repair wiring harness. (Open circuit)
Summary of Contents for 6 2002
Page 104: ...F 4 LOCATION INDEX End Of Sie FUEL SYSTEM A6E390001006W01 Engine Room Side A6E3912W015...
Page 151: ...F 36 EXHAUST SYSTEM A6E3914W002...
Page 312: ...F 182 TROUBLESHOOTING QUICK DIAGNOSTIC CHART A6E398018881W02 A6E3980W001...
Page 313: ...TROUBLESHOOTING F 183 F A6E3980W002...
Page 314: ...F 184 TROUBLESHOOTING A6E3980W003...
Page 315: ...TROUBLESHOOTING F 185 F End Of Sie A6E3980W004...
Page 410: ...K 3 K...
Page 526: ...TROUBLESHOOTING K 115 K QUICK DIAGNOSIS CHART A6E568001030W04 A6E5680W001...
Page 527: ...K 116 TROUBLESHOOTING End Of Sie A6E5680W002...
Page 653: ...ON BOARD DIAGNOSTIC ABS TCS P 57 P...
Page 701: ...TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL P 105 P Vehicle with ABS TCS A6E6980W002...
Page 819: ...OUTSIDE MIRROR S 60 2 THIS PAGE IS INTENTIONALLY LEFT BLANK End Of Sie...
Page 971: ...T 76 WARNING AND INDICATOR SYSTEM Operating Order A6E8118W009...
Page 1150: ...U 4 LOCATION INDEX End Of Sie CONTROL SYSTEM A6E850001042W01 L H D A6E8500W003 A6E8500W004...