U–50
CONTROL SYSTEM
1W
Potentiometer
signal
Airflow mode
actuator
VENT mode
4.3
•
Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
1W—C)
•
Inspect airflow mode
actuator
•
Inspect terminal voltage of
climate control unit (1B)
BI-LEVEL mode
3.3
HEAT mode
2.3
HEAT/DEF mode
1.5
DEFROSTER mode
0.6
1X
Hazard warning
SW signal
Hazard warning
switch
Hazard warning switch is
off
12
•
Inspect for continuity or
short circuit (Climate control
unit—flasher unit: 1X—H)
•
Inspect flasher unit
Hazard warning switch is
on
Below 1.0
•
Inspect terminal voltage of
climate control unit (1T)
•
Inspect center panel
2A
Panel light control
signal
Panel light control
switch
Headlight switch ON and
panel light control switch
at max. illumination
0.2
•
Inspect for continuity
(Climate control unit— panel
light control switch: 2A—C)
(Panel light control switch—
ground: C—GND)
•
Inspect panel light control
switch
Headlight switch ON and
panel light control switch
at min. illumination
10.2
•
Inspect for short circuit
(Climate control unit— panel
light control switch: 2A—C)
2B
TNS signal
TNS relay
Headlight switch OFF
Below 1.0
•
Inspect for short circuit
(Climate control unit—TNS
relay: 2B—D)
•
Inspect TNS relay
•
Inspect headlight switch
Headlight switch ON
12
•
Inspect for continuity or
short circuit (Climate control
unit—TNS relay: 2B—D)
•
Inspect TNS relay
•
Inspect headlight switch
2C
Motor drive signal
Air mix actuator
Moving to COLD
12
•
Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 2D—
D, 2C—F)
•
Inspect air mix actuator
Moving to HOT
Below 1.0
2D
Motor drive signal
Air mix actuator
Moving to HOT
12
•
Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 2C—
F, 2D—D)
•
Inspect air mix actuator
Moving to COLD
Below 1.0
2E
Motor drive signal
Airflow mode
actuator
Moving to DEFROSTER
12
•
Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
2E—F, 2G—D)
•
Inspect airflow mode
actuator
Moving to VENT
Below 1.0
2F
Backup power
supply
ROOM 15 A fuse
Under any condition
B+
•
Inspect for continuity or
short circuit (Climate control
unit—fuse: 2F— ROOM 15
A fuse)
•
Inspect ROOM 15 A fuse
2G
Motor drive signal
Airflow mode
actuator
Moving to VENT
12
•
Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
2G—D, 2E—F)
•
Inspect airflow mode
actuator
Moving to DEFROSTER
Below 1.0
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action
Summary of Contents for 6 2002
Page 104: ...F 4 LOCATION INDEX End Of Sie FUEL SYSTEM A6E390001006W01 Engine Room Side A6E3912W015...
Page 151: ...F 36 EXHAUST SYSTEM A6E3914W002...
Page 312: ...F 182 TROUBLESHOOTING QUICK DIAGNOSTIC CHART A6E398018881W02 A6E3980W001...
Page 313: ...TROUBLESHOOTING F 183 F A6E3980W002...
Page 314: ...F 184 TROUBLESHOOTING A6E3980W003...
Page 315: ...TROUBLESHOOTING F 185 F End Of Sie A6E3980W004...
Page 410: ...K 3 K...
Page 526: ...TROUBLESHOOTING K 115 K QUICK DIAGNOSIS CHART A6E568001030W04 A6E5680W001...
Page 527: ...K 116 TROUBLESHOOTING End Of Sie A6E5680W002...
Page 653: ...ON BOARD DIAGNOSTIC ABS TCS P 57 P...
Page 701: ...TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL P 105 P Vehicle with ABS TCS A6E6980W002...
Page 819: ...OUTSIDE MIRROR S 60 2 THIS PAGE IS INTENTIONALLY LEFT BLANK End Of Sie...
Page 971: ...T 76 WARNING AND INDICATOR SYSTEM Operating Order A6E8118W009...
Page 1150: ...U 4 LOCATION INDEX End Of Sie CONTROL SYSTEM A6E850001042W01 L H D A6E8500W003 A6E8500W004...
Page 1152: ...U 6 LOCATION INDEX R H D A6E8500W005 A6E8500W006...