ON-BOARD DIAGNOSTIC
U–57
U
Diagnostic Procedure
End Of Sie
DTC 07
A6E857001038W04
Diagnostic Procedure
End Of Sie
DTC 10
A6E857001038W05
Diagnostic Procedure
End Of Sie
DTC 11
A6E857001038W06
STEP
INSPECTION
ACTION
1
•
Is resistance between terminals 1I and 1M of
climate control unit connector (24-pin) as
indicated below?
—
137 ohms—220 kilohms
Yes
Replace climate control unit.
No
Go to next step.
2
•
Inspect cabin temperature sensor.
•
Is it okay?
Yes
Repair wiring harness.
No
Replace cabin temperature sensor.
DTC 07
Cabin temperature sensor system inspection
POSSIBLE
CAUSE
•
Cabin temperature sensor malfunction
•
Climate control unit malfunction
•
Open or short circuit between cabin temperature sensor and climate control unit
STEP
INSPECTION
ACTION
1
•
Inspect cabin temperature sensor.
•
Is it okay?
Yes
Go to next step.
No
Replace cabin temperature sensor.
2
•
Disconnect climate control unit connector
(24-pin) and cabin temperature sensor
connector.
•
Is there open circuit between the following
terminals of climate control unit connector
(24-pin) and cabin temperature sensor
connector?
— 1I—A
— 1M—B
Yes
Repair wiring harness.
No
Go to next step.
3
•
Is there short circuit to ground between
terminal 1M of climate control unit connector
(24-pin) and B of cabin temperature sensor
connector?
Yes
Repair wiring harness.
No
Connect climate control unit connector, then go to next step.
4
•
Turn the ignition switch to ON position.
•
Measure voltage at terminal the following
terminal 1M of climate control unit connector
(24-pin).
•
Is voltage
approximately 5V
?
Yes
This system is normal at present. (Erase the past failure
from memory.)
No
Replace climate control unit.
DTC 10
Evaporator temperature sensor system inspection
POSSIBLE
CAUSE
•
Evaporator temperature sensor malfunction
•
Climate control unit malfunction
•
Open or short circuit between evaporator temperature sensor and climate control unit
STEP
INSPECTION
ACTION
1
•
Is resistance between terminals 1I and 1Q of
climate control unit connector (24-pin) as
indicated below?
—
128 ohms—179 kilohms
Yes
Replace climate control unit.
No
Go to next step.
2
•
Inspect evaporator temperature sensor.
•
Is it okay?
Yes
Repair wiring harness.
No
Replace evaporator temperature sensor.
DTC 11
Evaporator temperature sensor system inspection
POSSIBLE
CAUSE
•
Evaporator temperature sensor malfunction
•
Climate control unit malfunction
•
Open or short circuit between evaporator temperature sensor and climate control unit
Summary of Contents for 6 2002
Page 104: ...F 4 LOCATION INDEX End Of Sie FUEL SYSTEM A6E390001006W01 Engine Room Side A6E3912W015...
Page 151: ...F 36 EXHAUST SYSTEM A6E3914W002...
Page 312: ...F 182 TROUBLESHOOTING QUICK DIAGNOSTIC CHART A6E398018881W02 A6E3980W001...
Page 313: ...TROUBLESHOOTING F 183 F A6E3980W002...
Page 314: ...F 184 TROUBLESHOOTING A6E3980W003...
Page 315: ...TROUBLESHOOTING F 185 F End Of Sie A6E3980W004...
Page 410: ...K 3 K...
Page 526: ...TROUBLESHOOTING K 115 K QUICK DIAGNOSIS CHART A6E568001030W04 A6E5680W001...
Page 527: ...K 116 TROUBLESHOOTING End Of Sie A6E5680W002...
Page 653: ...ON BOARD DIAGNOSTIC ABS TCS P 57 P...
Page 701: ...TROUBLESHOOTING ABS TCS DYNAMIC STABILITY CONTROL P 105 P Vehicle with ABS TCS A6E6980W002...
Page 819: ...OUTSIDE MIRROR S 60 2 THIS PAGE IS INTENTIONALLY LEFT BLANK End Of Sie...
Page 971: ...T 76 WARNING AND INDICATOR SYSTEM Operating Order A6E8118W009...
Page 1150: ...U 4 LOCATION INDEX End Of Sie CONTROL SYSTEM A6E850001042W01 L H D A6E8500W003 A6E8500W004...
Page 1152: ...U 6 LOCATION INDEX R H D A6E8500W005 A6E8500W006...