Monitoring
151
M
on
ito
rin
g
2: FDT-3
►
Activated when run frequency meets the following condition.
►
Active condition: Absolute value (FDT level - run frequency) <= FDT Bandwidth/2
Group
Code
Parameter Name
Setting Range
Default
Unit
I/O group
I52
[Detected Frequency
level]
-
0 - 400
30.00
Hz
I53
[Detected Frequency
Bandwidth]
-
10.00
Cannot be set above Max frequency (F21).
►
When setting I52 and I53 to 30.0Hz and 10.0 Hz, respectively