9.4 Analog Output
Group
Code
Parameter Name
Setting Range
Default
Unit
I/O group
I50
[Analog output item select]
-
0 - 3
0
I51
[Analog output level adjustment]
-
10 - 200
100
%
Output item and the level from the AM terminal are selectable and adjustable
►
I50: The selected item will be output to Analog output terminal (AM).
I50
Analog output
item select
Item corresponding to 10V
200V
400V
0
Output frequency.
Max Frequency (F21)
1
Output current
150% of Inverter rated current
2
Output voltage
282Vac
564Vac
3
Inverter DC link voltage
400Vdc
800Vdc
►
I51: If you want to use Analog output value as a gauge input, the value can be
adjustable according to various gauge specifications.