2NL/2P8
1-4-89
(2) Table of general classification
Error code
Description
U00000
No response or busy after the set number of redials.
U00100
Transmission was interrupted by a press of the stop/clear key.
U00200
Reception was interrupted by a press of the stop/clear key.
U00300
Recording paper on the destination unit has run out during transmission.
U004XX
A connection was made but interrupted during handshake with the receiver unit (See
page 1-4-92 ).
U00500
Multiple communication was interrupted and call was not made on destination units after
interruption.
U006XX
Communication was interrupted because of a machine problem (See page 1-4-93 ).
U00700
Communication was interrupted because of a problem in the destination unit.
U008XX
A page transmission error occurred in G3 mode (See page 1-4-93 ).
U009XX
A page reception error occurred in G3 mode (See page 1-4-93 ).
U010XX
Transmission in G3 mode was interrupted by a signal error (See page 1-4-94 ).
U011XX
Reception in G3 mode was interrupted by a signal error (See page 1-4-96 ).
U01400
An invalid one-touch key was specified during communication.
U01500
A communication error occurred when calling in V.8 mode.
U01600
A communication error occurred when called in V.8 mode.
U017XX
A communication error occurred before starting T.30 protocol during transmission in V.34
mode (See page 1-4-97 ).
U018XX
A communication error occurred before starting T.30 protocol during reception in V.34
mode (See page 1-4-98 ).
U02000
Relay broadcast was refused by a relay station because of a mismatch in permit ID num-
ber and permit telephone number when a relay command was issued.
U02100
A relay command failed because the destination unit (relay station) had no relay broad-
cast capability.
U02200
A relay command from a command station failed because a telephone number that was
not registered in the relay station was specified. Or, relay broadcast was requested to a
relay station but failed because a telephone number that was not registered in the relay
station was specified. Or, Subaddress-based relay broadcast transmission failed
because the data registered in the Subaddress relay box was deleted.
U023XX
Receiving station information was not normally received in reception of a relay command
(See page 1-4-98 ).
U02400
An interoffice subaddress-based relay transmission was interrupted because of a mis-
match in the specified relay box number.
U03000
No document was present in the destination unit when polling reception started.
U03100
In reverse polling, although no original was set in the destination unit, transmission was
complete.
U03200
In confidential polling reception, data was not accumulated in the specified box in the
destination unit. Or, in interoffice subaddress-based bulletin board reception, data was
not stored in the box specified by the destination unit.
Summary of Contents for TASKalfa 3010i
Page 10: ...This page is intentionally left blank ...
Page 100: ...2NL 2P8 1 2 76 This page is intentionally left blank ...
Page 286: ...2NL 2P8 1 3 186 This page is intentionally left blank ...
Page 443: ...2NL 2P8 1 5 59 This page is intentionally left blank ...
Page 471: ...2NL 2P8 2 2 8 This page is intentionally left blank ...
Page 532: ...Installation Guide DP 770 B Document processor DP 772 Document processor Installation Guide ...
Page 568: ...DP 773 Document processor Installation Guide ...
Page 594: ...PF 791 500 x 2 Paper feeder Installation Guide ...
Page 602: ...PF 810 3000 sheet deck Installation Guide ...
Page 615: ...DF 791 3000 sheet finisher Installation Guide ...
Page 630: ...DF 770 D 1000 sheet finisher Installation Guide ...
Page 648: ...AK 740 Bridge unit Installation Guide ...
Page 650: ...MT 730 B Mailbox Installation Guide ...
Page 665: ...PH 7A C D Punch unit Installation Guide ...
Page 686: ...DT 730 B Document tray Installation Guide ...
Page 731: ...5 2013 5 302LC56750 01 H F G D D 6 4 3 7 E C D D M4 8 M4 8 M4 8 M4 8 ...
Page 732: ...FAX System W B Installation Guide ...