546
Jetter AG
10 Programming
CAN message box - Description of registers for direct access
For programming purposes, always use registers for direct access to message
boxes. 20 registers with identical functions are assigned to each message
box. The registers of individual message boxes start from a certain basic
register number.
Message box number
Basic register number
0
R 200010530
1
R 200010550
2
R 200010570
3
R 200010590
4
R 200010610
5
R 200010630
6
R 200010650
7
R 200010670
8
R 200010690
9
R 200010710
10
R 200010730
11
R 200010750
12
R 200010770
13
R 200010790
14
R 200010810
15
R 200010830
20 registers with identical functions are assigned to each message box. The
register number of individual message boxes is calculated from the basic
register number and the message box number (0 ... 15).
Register
Description
R 200
message box number *20
Message box status register
R 200
message box number *20
Message box configuration register
R 200
message box number *20
CAN-ID
R 200
message box number *20
Number of data bytes
R 200
message box number *20
Data byte 0
R 200
message box number *20
Data byte 1
Direct access
Registers for message
boxes of the CAN-Prim
interface
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......