The user-programmable IP interface allows to send or receive any data via
Ethernet interface on the JC-120MC using TCP/IP or UDP/IP. When using this
feature, data processing is completely carried out by the application program.
The user-programmable IP interface allows the programmer to carry out data
exchange via Ethernet connections which do not use standard protocols, such
as FTP, HTTP, JetIP or Modbus/TCP. The following applications are possible:
Server
Client
TCP/IP
UDP/IP
To be able to program user-programmable IP interfaces the following
knowledge of data exchange via IP networks is required:
IP addressing (e.g. IP address, port number, subnet mask)
TCP (e.g. connection establishment/termination, data stream, data backup)
UDP (e.g. datagram)
For communication via user-programmable IP interface, the programmer must
not use any ports which are already used by the operating system of the
controller. Therefore, do not use the following ports:
Protocol
Port number
Default value
User
TCP
Depending on the
FTP client
20
FTP server (data)
TCP
21
FTP server (controller)
TCP
23
System logger
TCP
80
HTTP server
TCP
From the file
/EMAIL/email.ini
25, 110
E-mail client
TCP
502
Modbus/TCP server
TCP, UDP
1024 - 2047
Various
TCP, UDP
IP configuration
50000, 50001
JetIP
TCP
IP configuration
52000
Debug server
The user-programmable
IP interface
Applications
Required programmer's
skills
Restrictions
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......