![Jetter JC-120MC User Manual Download Page 106](http://html1.mh-extra.com/html/jetter/jc-120mc/jc-120mc_user-manual_3870525106.webp)
106
Jetter AG
4 Mechanical and electrical installation
4.8 Configuring the JX2 system bus
This chapter is on configuring the JX2 system bus.
The following table shows the maximum number of modules which you can
connect in parallel to the JX2 system bus of the JC-120MC.
Controller
JX2-I/O modules
IP67 modules
JX-SIO
CANopen® modules
JX2 slave modules
JetMove
JC-120MC-4
23
10
4
JC-120MC-8
23
10
8
JC-120MC
23
10
16
The following modules can be connected to the JX2 system bus of a
JC-120MC:
JX2-I/O modules
JX2 slave modules
Servo amplifiers JetMove 1xx, JetMove 2xx, and JetMove 6xx
IP67-I/O modules LioN-S and LJX7-CSL
JX-SIO and Smart I/O
The following third-party CANopen® modules can be connected to the system
bus of the JC-120MC:
Valve terminals by Festo
Valve terminals by SMC
Valve terminals by Bürkert
I/O system 750 by Wago
Gateway BWU1821 by Bihl+Wiedemann
EcoStep drives by Jenaer Antriebstechnik
EPOS drives by maxon
Drives by Festo
Drives by Lenze
Milan drive by GFC
Topic
Page
Wiring the JX2 system bus ......................................................................... 107
Introduction
Number of connectable
modules
Supported modules
Third-party CANopen®
modules
Contents
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......