5 Initial commissioning
Preparatory work for initial commissioning
The JC-120MC in delivered condition has got IP address 192.168.1.1.
Configure the Ethernet interface of your PC so that it communicates with the
controller via this IP address.
If the mode selector is in position
STOP
when the controller is powered-up,
the application program will not be launched.
Following a correct commissioning, the LEDs are lit as follows:
R
SD
U1
U3
U4
U2
E D1 D2
JC
-3
xx
Jetter
LED
State
Description
R
1Hz
Logic voltage supply is OK; application program has been
stopped.
E
OFF
No error
D1
OFF
No error
D2
OFF
No error
SD
OFF
The controller does not access the SD card.
U1 - U4
OFF
LEDs which are programmed depending on the
application
Ethernet connection with
the controller
Behavior after power-up
Status of the LEDs