Jetter AG
345
JC-120MC
Programming
Cursor position
This parameter is used to define the screen position where the first character
of the text or variable is to appear.
There is no cursor position evaluation for devices 8 through 11.
Cursor position
0
has a special meaning. The controller evaluates this
parameter in the following steps:
Step
Description
1
The controller reads the content of MR 2814.
2
If ...
... then ...
... MR 2814 is larger than 0,
... the value is used as cursor
position.
... MR 2814 equals 0,
... the message is displayed starting
from the current cursor position.
Example: MR 2814 = 0
DisplayText(
0
,
1
,
'Temp :'
);
DisplayValue(
0
,
0
, Temperature);
Result
: The temperature is displayed directly after the colon starting from
cursor position 7.
Indirect cursor position
This module register specifies the cursor position, if
0
has been programmed
as parameter.
Module register properties
Values
0 ... Number of characters on the screen
Value after reset
0
Introduction
Restrictions
Cursor position 0
MR 2814
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......