![Jetter JC-120MC User Manual Download Page 339](http://html1.mh-extra.com/html/jetter/jc-120mc/jc-120mc_user-manual_3870525339.webp)
Jetter AG
339
JC-120MC
Programming
Setting the format of numerical values
In setting the format of numerical values you have the choice between decimal
or hexadecimal format. Flag 2060 lets you set the format of numerical values.
Format of numerical values
Flag properties
Values
0
Decimal
1
Hexadecimal
Takes effect
Next time when STX instruction
DisplayValue()
is issued
Setting the format of
numerical values
Flag 2060