610
Jetter AG
15 Quick reference - JC-120(MC)
222831
Basic flag number for display 3
222832
Basic flag number for display 4
222833
Register number - LED display 1
222834
Register number - LED display 2
222835
Register number - LED display 3
222836
Register number - LED display 4
222837
Module number of PRN (display redirection)
222838
Module number of SER (display redirection)
222839
Character code for
Delete display
222840
Character code for
Delete to end of line
Networking via JetIP
TCP auto-close for the JetIP/TCP server
230000
Number of open connections
230001
Mode
230002
Time
Other registers for networking via JetIP
232708
Timeout in milliseconds
232709
Response time in milliseconds
232710
Amount of network errors
232711
Error code of last access
0 = No error
1 = Timeout
3 = Error message from the remote station
5 = Invalid network address
6 = Invalid amount of registers
7 = Invalid interface number
232717
Max. number of retries
232718
Number of retries
Network registers
235000 ...
235399
IP addresses
235400 ...
235799
Port numbers
236000 ...
236399
Indirect register numbers
GNN: nnn = 000 ... 199
1nnn020000 ...
1nnn179999
JX3 module registers
1nnn202000 ...
1nnn227999
JX2 module registers
1nnn810000 ...
1nnn819999
JetMove registers
1nnn980000 ...
1nnn980199
Indirect access via local register 236xxx
1nnn990000 ...
1nnn999999
Indirect access with variable target window
Ethernet system bus
Subscriber
250000
Status (bit-coded)
Bit 0 = 1: No CRC
Bit 1 = 1: Error in connection with a subscription
Bit 7 = 1: Subscriber is running
250001
Command
102: Restart
105: STOPP
110: Acknowledge error
250002
Subscription ID of the last error
250003
Number of subscriptions
250004
CRC of configuration file
250010
Selection via command
250011
Selection via ID
Subscription
250020
Status
250021
Mode
250022
Number of elements
250023
Multicast group
250024
Hash
250025
Current sequence number
250026
Size (bytes)
250027
Timeout
250028
Number of received publications
250029
Number of timeout errors
250030
Amount of sequence number errors
250100 ...
250999
9 more subscriber register blocks
Address of the bus node (or controller) exceeding
the timeout time
254001
GNN
254002
IP address
254003
Port number
Publisher
255000
Status (bit-coded)
Bit 0 = 1: No CRC
Bit 1 = 1: Error in connection with a publication
Bit 7 = 1: Subscriber is running
255001
Command
102: Restart
105: STOPP
110: Acknowledge error
255002
Publication ID of the last error
255003
Number of publications
255004
CRC of configuration file
255010
Selection via command
255011
Selection via ID
Publication
255020
Status
255021
Mode
255022
Number of elements
255023
Multicast group
255024
Hash
255025
Current sequence number
255026
Size (bytes)
255027
Cycle time
255028
Number of publications sent
255029
Number of retries
255030
Number of transmit errors
255100 ...
255999
9 more publisher register blocks
RemoteScan
262965
Protocol type
262966
Amount of configuration blocks
262967
Status
Modbus/TCP
272702
Register offset
272704
Input offset
272705
Output offset
278000 ...
278999
16-bit I/O registers overlaid by virtual I/Os 20001 ...
36000
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......