Jetter AG
573
JC-120MC
Automatic copying of controller data
Parameter name 2
Destination
Parameter value 2
Complete name of the destination file
Allowed values
All allowed file names
The destination directory does exist
Illegal values
Incorrect filename
Non-existent source file
Non-existent destination directory
In the event of an illegal
value
The controller does not copy the file. It enters the error
into the log file.
Example
[COMMAND_1]
Command = FileCopy
Source =
/SD/OS/JC-120MC_1.26.1.00.os
Destination = /System/OS/op_system.os
[COMMAND_2]
Command = FileCopy
Source = /SD/Manual.pdf
Destination = /sub1/Manual.pdf
Command = FileRemove
Function
Deleting a file
Parameter name
Path
Parameter value
Complete name of the file
Allowed values
All allowed file names
Illegal values
Incorrect filename
In the event of an illegal
value
The controller does not delete the file. It enters the error
into the log file.
Example
[COMMAND_5]
Command = FileRemove
Path = /sub1/Manual.pdf
Command = DaFileRead
Function
Transferring register values and flag states from a data
file to the JC-120MC
Parameter name
DaFile
Parameter value
Complete name of the data file
Allowed values
All allowed file names for data files
Illegal values
Incorrect filename
Nonexistent data file
In the event of an illegal
value
The data are not transmitted to the JC-120MC. The
JC-120MC enters the error into the log file.
Example
[COMMAND_12]
Command = DaFileRead
DaFile = /SD/Data/MyTestData.da
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......