478
Jetter AG
10 Programming
Configuring the interface
Module registers MR 1 through MR 6 are used to configure the
user-programmable serial interface.
This guide proceeds from the assumption that wiring between controller and
remote device is according to the standard of the selected interface.
To configure the user-programmable serial interface proceed as follows:
Step
Action
1
Enter value 1 into MR 2.
2
Enter the desired communication parameters into MR 2 through MR 6.
Result:
The serial interface is set as user-programmable interface. Both the
transmit buffer and receive buffer are cleared.