320
Jetter AG
10 Programming
Configuring the screen size manually
To configure the screen size manually, proceed as follows:
Step
Action
1
Enter the number of characters per line into MR 2805.
2
Multiply the value contained in MR 2805 by the number of lines and enter
the result into MR 2804.
Number of characters on the screen
This module register contains the number of characters displayed on the
screen.
Module register properties
Values
1 ... 128
Value after reset
48
Number of characters per line
This module register contains the number of characters per line.
Module register properties
Values
1 ... 128
Value after reset
24
Configuring the screen
size manually
MR 2804
MR 2805