264
Jetter AG
10 Programming
Number of cycles
Corresponds to the feedback value
Count
.
Module register properties
Values
0 ... 3
Number of cycles
Type of access
Read
Number of changes
Corresponds to the feedback value
Changed
.
Module register properties
Values
0 ... 199
Number of changed network nodes
Type of access
Read
Result of the function
Corresponds to the feedback value
Result
and the register content of the
global error number 2000051. This register indicates the value of the latest
error or warning. Values greater than zero indicate warnings. Values smaller
than zero are error messages.
Module register properties
Values
0
No error or warning
5
The user has terminated the function
1001
The first received response does not match
response 2 and 3 (see MR 101x)
1002
The second received response does not
match response 1 and 3 (see MR 102x)
1003
The third received response does not match
response 1 and 2 (see MR 103x)
-1
All 3 responses are dissimilar (see
MR 100x)
-2
The IP settings of at least one node could
not be changed (see MR 140x)
-3
The JetIPScan function has been invoked,
although it is active already
-10
The length of the set value list is < 1 or
> 255, or the pointer to the list is invalid
-11
A GNN of the set value list is < 1 or > 255, or
it is a multiple GNN
Values
-20 ... -40
Internal error
MR 11
MR 12
MR 13
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......