500
Jetter AG
10 Programming
Register description
The operating system manages the established connections in a list. Module
register MR 0
Selection of a connection
is used to copy connection details into
other registers of a register block.
Selecting a connection
Connections are selected by writing values to this register. Read access to
this register is used to display whether the following registers contain
connection details.
Module register properties
Reading values
0
Connection exists
-1
Connection does not exist
Module register properties
Writing values
0
Address the first connection in the list
> 0
Address the next connection in the list
< 0
Address the previous connection in the list
Type of connection
The value in this register shows whether the connection is a client or a server
connection.
Module register properties
Values
1
Client
2
Server
Transport protocol
The value in this register shows whether TCP or UDP is used as transport
protocol.
Module register properties
Values
1
UDP
2
TCP
Introduction
MR 0
MR 1
MR 2
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......