![IAI SCON-CB-F Instruction Manual Download Page 80](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055080.webp)
2. Wiring
64
6) PIO Pattern 5 ············· Solenoid Valve Mode 2 (3-point type)
0V(NPN Type)
24V DC
Supply
1A
P24
1B
0V
Supply
24V DC(NPN Type)
24V DC(PNP Type)
2A
P24
2B
0V(PNP Type)
Start Signal 0
Start Signal 2
Start Signal 1
3A
ST0
LS0
LS1
LS2
3B
4A
ST1
4B
5A
ST2
5B
6A
6B
7A
7B
8A
ZONE1
8B
9A
BKRL
9B
10A
RMOD
RMDS
10B
Backward End Detection
Forward End Detection
Intermediate Position Detection
11A
HEND
11B
12A
12B
13A
SV
13B
Reset
14A
RES
*EMGS
14B
Servo ON
15A
SON
*ALM
*BALM
15B
16A
16B
17A
N
17B
18A
N
18B
19A
19B
20A
20B
SCON
PIO
Connector
Alarm
Servo ON Status
Emergency Stop Status
Absolute Battery
Voltage Drop Warning Output
Zone
Operating Mode Status (Manual Mode)
Home Return Completion
Brake Control Release
Operation Mode Changeover
BR- 1
RD- 1
OR- 1
YW- 1
GN- 1
BL- 1
PL- 1
GY- 1
WT- 1
BK- 1
BR- 2
RD- 2
OR- 2
YW- 2
GN- 2
BL- 2
PL- 2
GY- 2
WT- 2
BK- 2
BR- 3
RD- 3
OR- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4
PZONE
/ZONE2
Position Zone/Zone 2
“*” in codes above shows the signal of the active low. Processing occurs when an
input signal of the type is turned OFF. An output signal of the type is normally ON
in the power-on status and turned OFF at signal output.
2.1.3
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......