![IAI SCON-CB-F Instruction Manual Download Page 350](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055350.webp)
9. T
roubleshooting
334
9.4 Alarm List
Alarm
Code
Alarm
Level
Alarm Name
Cause/Treatment
02E
Calendar function related
command in calendar
function invalid status
Cause
: An attempt was made to use the calendar in the
state where the RTC (calendar) function was made
ineffective.
Treatment : Set parameter No.111 (Selection of use of calendar
function) to “1” (“0”: no use).
048
Driver Overload Alarm
Cause
: The load current exceeded the value set in
Parameter No.143 “Overload Level Ratio”.
This alarm is kept alarm condition until reset is
made. This alarm turns ON when the load current
exceeds the setting from a value below the setting.
Treatment : Lower the setting of acceleration/deceleration. Also,
increase the frequency of pause.
04C
Drop in Number of Fan
Revolution
Cause
: The number of the FAN revolution has dropped to
the warning level.
Treatment : Degradation of the fan can be considered. Replace
the FAN.
04D
Excess Fan Total
Operational Duration
Cause
: The total operation duration of the FAN has
exceeded the reference timing for replacement.
This alarm is not purposed to indicate an error.
Treatment : Utilize this alarm as a reference for the timing to
replace the FAN.
04E
Exceeded movement
count threshold
Cause
: The total number of the operation times exceeded
the value set in Parameter No.147 “Total Movement
Count Threshold”.
04F
Exceeded operated
distance threshold
Cause
: The total number of the operation distance
exceeded the value set in Parameter No.148 “Total
Operated Distance Threshold”.
068
SRAM access error
Cause
: Servo monitor is not operated in the normal
condition because of noise or malfunction of
consisting parts.
Treatment : 1) Take proper measures against noise.
2) When the servo monitoring function is not used,
set parameter No.112 “Monitoring mode” to “0”.
3) If the operation is not improved in use of the
servo monitoring function in spite of measures
against noise, Please contact IAI.
069
Detection of realtime clock
oscillation stop
Cause
: The calendar function is stopped and the current
time data is lost.
Treatment : Set the time again.
[Refer to the Instruction Manual of RC PC software.]
(Note) This error is not registered in the alarm list.
06A
Realtime clock access
error
Cause
: The calendar function is not working properly
because of noise or malfunction of consisting parts.
Treatment : 1) Take proper measures against noise.
2) When the calendar function is not used, set
parameter No.111 “Calendar function” to “0”.
3) If the operation is not improved in use of the
calendar function in spite of measures against
noise, Please contact IAI.
06B
Message
Maintenance information
data error
Cause
: The maintenance information (total movement
count, total operated distance) is lost.
Treatment : Please contact IAI.
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......