2.3.2 I/O Signals in Pulse Train Control Mode
The table below shows the signal assignment of the flat cable in the pulse train control mode.
Have the PIO Pattern setting revised considering the actuator specifications (Incremental/Absolute).
Follow the following table to connect the external equipment (such as PLC).
{
: Available,
°
: Unavailable
PIO
Pattern
0
(Incremental)
1
(Absolute)
Pin
No. Category I/O No.
Signal
Abbreviation
Signal Name
Function Description
Relevant
Sections
1A
24V
P24
Power Supply
Power Supply for I/O +24V
{
{
2A
24V
P24
Power Supply
Power Supply for I/O +24V
3A
–
NC
–
Not used
4A
–
NC
–
Not used
5A
IN0
SON
Servo ON
The servo remains ON while this signal is ON, or OFF
while this signal is OFF.
3.3.2
6A
IN1
RES
Reset
Turn the signal ON to reset the alarm.
3.3.2
7A
IN2
HOME
Home Return
The controller will perform home return operation
when this signal is turned ON.
3.3.2
8A
IN3
TL
Torque Limit
Select
Puts torque limitation to the motor with the signal ON
and the value set to the parameter.
3.3.3
9A
IN4
CSTP
Compulsory Stop
Turning it ON continuously for more than 10ms
compulsorily stops the actuator.
The actuator decelerates then stops with the torque
set in the controller and then turns the servo OFF.
3.3.2
10A
IN5
DCLR
Deviation
Counter Clear
Clears the deviation counter.
3.3.3
11A
IN6
BKRL
Brake Forcible
Release
The brake will forcibly be released.
3.3.2
{
12A
IN7
RMOD
Operation Mode
Changeover
The operating mode is selectable when the MODE
switch of the controller is set to AUTO. (The setting is
AUTO when signal is OFF, and MANU when ON.)
3.3.2
°
{
13A
IN8
RSTR
Datum Position
Movement
Command
Movement is made to the position set in Parameter
No. 167 when the signal is turned ON. (Applicable
only to pulse train mode PIO pattern 1)
3.3.2
14A
IN9
NC
–
Not used
15A
IN10
NC
–
Not used
16A
IN11
NC
–
Not used
17A
IN12
NC
–
Not used
18A
IN13
NC
–
Not used
19A
IN14
NC
–
Not used
20A
Input
IN15
NC
–
Not used
1B
OUT0
PWR
System Ready
This signal turns ON if SCON is controllable after
main power ON.
3.3.2
2B
OUT1
SV
Servo ON Status This signal will remain ON while the servo is ON.
3.3.2
3B
OUT2
INP
Position
Complete
Turned ON when the remaining moving pulses in the
deviation counter enters within the positioning band.
3.3.3
4B
OUT3
HEND
Home return
completion
This signal will turn ON when home return has been
completed.
3.3.2
5B
OUT4
TLR
Torque Under
Control
Turns ON if the torque reaches the limit value during
torque limit.
3.3.3
6B
OUT5
*ALM
Controller Alarm
Status
Turns ON when controller in normal condition, and
OFF when alarm is generated.
3.3.2
7B
OUT6
*EMGS
Emergency Stop
Status
Turns ON when the controller emergency stop is
cancelled, and OFF during the emergency stop.
3.3.2
8B
OUT7
RMDS
Operation Mode
Status
The operating mode status will be output. It turns ON
when the controller is on Manual Mode.
3.3.2
9B
OUT8
ALM1
10B
OUT9
ALM2
11B
OUT10
ALM4
12B
OUT11
ALM8
Alarm Code
Output Signal
The alarm code is output together with the alarm
signal output.
Refer to Alarm List for details.
3.3.2
{
13B
OUT12
*OVLW/
*ALML
Overload Alarm/
Light Error Alarm
Turns OFF if exceeded the overload warning
threshold (set in Parameter No.143) when Parameter
No.151 is set to 0 (Overload Warning).
It turns OFF when the message level alarm is
generated if Parameter No.151 is set to 1 (Light Error
Alarm).
3.3.2
°
14B
OUT13
REND
Datum Position
Movement
Complete
Turns ON when movement to the datum position set
in Parameter No. 167 is finished. (Applicable only to
pulse train mode PIO pattern 1)
3.3.2
15B
OUT14
ZONE1
Zone Signal 1
{
{
16B
Output
OUT15
ZONE2
Zone Signal 2
This signal will turn ON when the current actuator
position enters the range set by the parameters.
3.3.2
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......