![IAI SCON-CB-F Instruction Manual Download Page 193](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055193.webp)
3. Operation
177
[2] Speed change during the movement
Sample use
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
0
1 150.00 250.00 0.20 0.20
0
0
0.10
0.00
0.00
0
0
0
0
2 0.00 50.00 0.20 0.20
0
0
100.00
0.00
0.00
0
0 0
0
3 0.00 100.00 0.20 0.20
0
0
0.10
0.00
5.00
0
0
0
0
Control method
The speed of the actuator can be changed while it moves. Positions are used by the number of
speeds. The method of controlling the operation to each position is the same as that described
in [1] Positioning.
The example below describes the case of 2 speeds:
1) In this example, the speed is changed while the actuator moves from the position of
150mm to the position of 0mm. At first, set the positioning to the target position at the first
speed in position No.2. In the positioning width, set the distance from the speed change
position to the target position. The value is set to 100mm in the example. Thus, for position
No.2, positioning complete signal PEND is turned ON at the position before the target
position by 100mm.
2) Set the positioning to the target position at the second speed in position No.3.
3) Start position No.2. Then start position No.3 successively when PEND in position No.2 is
turned ON. In normal positioning, position data specified later has always a priority over
position data specified earlier. Thus, the operation in position No.3 is started on the way of
the operation in position No.2.
In this example, the target positions No.2 and 3 are equal with each other. They may not be the
same. However, setting the target positions to be equal with each other allows the distance
from the speed change position to the target position to be known easily.
To increase in the number of speed change steps, add a position number and operation
sequence, set the speed change position in the positioning width and operate the actuator
continuously.
Positioning
Completion
Signal Output
Velocity
Positioning
Completion
Signal Output
1)
2)
3)
4)
5)
6)
7)
1) 2)
3)
5)
4)
6) 7)
Positioning complete width at position 2
3.2.4
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......