3. Operation
235
{
: ON
z
: OFF
*ALM ALM8 ALM4 ALM2 ALM1 Binary Code
Description: Alarm code is shown in ( ).
z
{
z
z
{
9
Electromagnetic Brake Unrelease Error (0A5)
Dynamic brake not released (0A6)
Overcurrent (0C8)
Overheat (0CA)
Current Sensor Offset Adjustment Error (0CB)
Emergency stop relay fused (0CD)
Drop in control supply voltage (0CE)
I/O 24V Power Supply Error (0CF)
z
{
z
{
{
11
Command counter overflow (0A4)
Electric Angling Mismatching (0B4)
Deviation Overflow (0D8)
Software stroke limit exceeded (0D9)
Feed Back Pulse Error (0DA)
z
{
{
z
z
12
Motor Power Source Voltage Excessive (0D2)
Motor power-supply voltage low (0D3)
Belt-breaking sensor detected (0D7)
Overload (0E0)
Driver logic error (0F0)
z
{
{
z
{
13
Linear ABS Error (0B3)
Encoder send error (0E4)
Encoder Receipt Error (0E5)
Encoder count error (0E6)
A-, B- and Z-phase Wire Breaking (0E7)
Battery-less ABS Error (0EB)
Absolute Encoder Error Detection 2 (0EE)
z
{
{
{
z
14
CPU Error (0FA)
FPGA Error(0FB)
Logic Error (0FC)
z
{
{
{
{
15
Nonvolatile memory write verify error (0F5)
Nonvolatile memory write timeout (0F6)
Nonvolatile memory data destroyed (0F8)
(Note) *ALM Signal is an active low signal. It is ON when the power is applied to the controller, and
turns OFF when the signal is output.
3.3.2
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......