1. Specifications Check
37
● Types for 3000W and above
It is a unit to convert the regenerative current generated at motor deceleration into heat.
Refer to 2.6.6 Connection of Regenerative Unit for the number of connectable units.
[Model, Accesories]
Model
Accessories
RESU-35T
None
[Specifications]
Item
Specification
Main Unit Dimension [mm]
W45 × H300 × D197
Main Unit Mass
Approx. 1.8kg
Built-in Regenerative Resistor
30
Ω
450W
Operation Temp.
130
°
C ±5
°
C
Contact Format
Contact b
Built-in Temp.
Sensor
Contact Open-Close
Capacity
DC30V (MAX.) 200mA (MAX.)
[External Dimensions]
Caution: The temperature for the external regenerative resistor units get high.
•
Do not attempt to install the unit near a flammable object.
•
Do not attempt to touch them.
•
It is recommended that the cables to be used should possess high performance in the
heat resistance. Also, pay attention to have the cables not to touch the external
regenerative resistor units.
•
The unit is equipped with a built-in temperature sensor. Establish the circuit constructed to
cut off the power source when the temperature sensor is in operation.
•
Attach a fan unit if necessary. There are tapped holes equipped so a fan unit sized 80mm
□80mm can be installed.
[Reference] Specifications for External Fan Unit
Item
Specification
Size
□80mm
Air Blow Volume
0.45m
3
/min. or more
Direction of Air Blow
Blow air against resistors
Installation
M4 Screw length: Thickness of fan unit + 6mm max.
Position to install fan unit
and tapped hole for
installation (air blow)
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......