![IAI SCON-CB-F Instruction Manual Download Page 133](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055133.webp)
2. Wiring
117
● Wiring Method
Connect the wires for operation stop (System I/O Connector) to the enclosed connector (Model
code: FMC1.5/4-ST-3.5: Phoenix Contact).
See below for how to lay out the power supply wires.
1) Loosen the terminal screw with using such as a slotted screwdriver to open up the inlet.
2) Reveal the sheath for 10mm on the cable that satisfies the cable diameter complies the
specification shown in the table below and put it in the inlet.
3) Tighten the terminal screw with using such as a slotted screwdriver. The inlet closes and
affixes the wire.
4)
Connect all the wires in the same manner and insert the enclosed connector to the
power connector.
System I/O Connector
Pin No.
Signal Name
Contents
Applicable cable diameter
1
S1
Operation Stop Switch Contact
2
S2
Operation Stop Switch Contact
3
EMG+
Operation Stop Dedicated
Power Output
4
EMG-
Operation Stop Input
1.25 to 0.5mm
2
(AWG16 to 20)
1) Push in a slotted
screwdriver to the
protruded area
2) Insert wire
Wire Inlet
Protruded Area
Pin Number and
Signal Name
1. S1
2. S2
3. EMG+
4. EMG-
Enclosed Part
3) Plug in the enclosed connector to
the power connector on the
controller side
2.5.2
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......