3. Operation
166
[5] Zone Signal and Position Zone Signal (ZONE1, PZONE)
Output
PIO signal
ZONE1
(Note 2)
PZONE
(Note 2)
Pattern 0
{
{
Pattern 1
×
{
Pattern 2
×
{
Pattern 3
(Note 1)
×
×
Pattern 4
{
{
Pattern 5
{
{
Pattern 6
×
{
Pattern 7
×
{
{
: Available,
×
: Unavailable
Note 1 Pattern 3 does not have the zone signal output feature.
Note 2 PZONE Signal can be changed to ZONE1 and ZONE2 Signals by the setting in
Parameter No.149.
The relevant signal can be turned ON while the actuator passes or stops in the zone range in
either of the following 2 types:
1) Zone signal (ZONE1)················The output signal is turned ON at the position set by the
proper parameter.
2) Position zone signal (PZONE) ····The output signal is turned ON at the position set in the
position table.
The feature can play a role as the sensor for judging whether the completion position is good or
not at completion of pressing, setting the continuous operation zone in pitch feed or interlocking
operations of other units in the setting zone.
(1) Zone signal (ZONE)
Set the zone range to the relevant parameter.
1) Parameter No.1 : Zone boundary 1+
2) Parameter No.2 : Zone boundary 1-
The zone signal ZONE is kept effective also during the emergency stop unless the memory of
the origin is lost due to alarm.
Time
Velocity
Zone output signal
1)
2)
3)
4)
5)
1)
2)
3)
4) 5)
3.2.3
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......