8. Parameter
310
[82] Calendar function (Parameter No.111)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
111 Calendar function
FRTC
–
0: Does not use the
calendar timer
1: Use the calendar
timer
1
This parameter defines whether the calendar function (RTC) is used or not.
Set the current time with using a teaching tool when the calendar function is used.
[Refer to the instruction manual of the teaching tool for the details.]
In use of RTC, the alarm occurrence time in the alarm list is the time at which an alarm has
occurred.
If RTC is not used, the time of alarm issuance shown in the alarm list counts the time passed
since the power is supplied to the controller counted as 0 second.
The time data retainable duration with no power supply to the controller is approximately
10 days.
Set Value
Description
0
Not Applicable
1
Use
[83] Monitoring mode (Parameter No.112)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
112 Monitoring mode
FMNT
–
0: Does not use
1: Monitor function 1
2: Monitor function 2
3: Monitor function 3
1
The controller can be connected with PC software to monitor the servo.
This parameter allows you to select a monitoring mode function (servo monitor).
Check the Instruction Manual of the RC PC software for details.
Set Value
Description
0
Unused
1
Sets the 4CH-30000 record mode.
2
Sets the 8CH-15000 record mode.
3
Sets the 2CH-60000 record mode.
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......