8. Parameter
311
[84] Monitoring period (Parameter No.113)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
113 Monitoring period
FMNT
msec
1 to 1000
1
This is the parameter to set up the frequency of time to obtain data (Sampling Frequency) when
the monitoring mode is selected.
By setting the value in this parameter bigger, the frequency of data obtaining can be made
longer.
It is set to 1 ms in the initial setting. Up to 1000 ms can be set.
1 ms frequency setting
1000 ms frequency setting
Up to 30 seconds in 4CH-30000 record
mode
Up to 30000 seconds (500 minutes) in
4CH-300000 record mode
Up to 15 seconds in 8CH-15000 record
mode
Up to 15000 seconds (250 minutes) in
8CH-150000 record mode
Up to 60 seconds in 2CH-60000 record
mode
Up to 60000 seconds (1000 minutes) in
2CH-600000 record mode
[85] Selecting used feedback pulse gear ratio (Parameter No.114)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
114 Selecting used feedback pulse
gear ratio
FPIO
–
0: Not Applicable
1: Use
0
Refer to 3.3.5 Output Settings of Feedback Pulse when using the product with Pulse Train
Control Mode.
Feedback pulse is available for the output also other than Pulse Train Control Mode. In this
case, select “1”.
Set Value
Description
0
Outputs feedback pulses using the electronic gear ratio defined by
parameter No.65 and 66 (command pulse-train) (initial value)
1
Outputs feedback pulses using the electronic gear ratio defined by
parameter No.115 and 116.
[86] Electrical Gear (Feedback Pulse) (Parameter No.115, No.116)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
115 Electronic gear numerator
(Feedback Pulse)
FNUM
–
1 to 99999999
125
116 Electronic gear denominator
(Feedback Pulse)
FDEN
–
1 to 99999999
2048
The input range is from 1 to 4096 if the controller version is earlier than V0005.
Refer to 3.3.5 Output Settings of Feedback Pulse for the details.
The setting is the same for the cases other than Pulse Train Control Mode.
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......