2. Wiring
144
2.6.7 SIO Connector Connection
SIO connectors can be used not only for the connection of teaching tool, but also for the connection
of the host controller (PLC, touch panel and PC).
For the operation, refer to the instruction manual of each module.
Item
Items and Model
Connector Name
SIO Connector
Cable Side
miniDIN 8 Pin
Controller Side
TCS7587-0121077
Pin No. Signal name
Items
Applicable cable diameter
1
SGA
Teaching tool
2
SGB
Teaching tool signal-
3
5V
Power supply for teaching tool
4
ENB
Enable signal input
5
EMGA
Emergency stop signal A
6
24V
Power supply for teaching tool
7
0V
0V
8
EMGB
Emergency stop signal B
Shell
0V
0V
Dedicated connection cables
provided by us
Caution: If the controller is connected with a teaching device, set the operation mode
setting switch to MANU.
Removing the SIO connector while the power is ON causes a transient
emergency stop. Thus, the devices such as the actuator which are in
operation will stop.
Do not disconnect the SIO connector during the operation.
In case the SIO connector is not used, make sure to insert the dummy plug
DP-5 for teaching pendant.
Dummy Plug DP-5
PC
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......