![IAI SCON-CB-F Instruction Manual Download Page 291](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055291.webp)
7.
Absolute Reset and
Absolute Battery
275
Voltage
PIO Signals
Alarm
3.1V (Reference value)
Voltage drop alert signal *BALM
(Note 2)
OFF
–
2.5V (Reference value)
Alarm signal *ALM
(Note 2)
OFF
OEE Absolute Encoder Error
Detection 2
or
OEF Absolute Encoder Error
Detection 3
Note 2 *BALM and *ALM are the signals of active low.
After the power is supplied to the controller, they are usually on and turned OFF when
an error is detected.
Replace the battery before alarm is generated due to the lamp display by *BALM signal
of PLC.
If the alarm is generated, it will be necessary to absolute reset after the battery
replacement.
Normal
3.6V
3.1V
2.5V
W
arning occurre
d
Alarm
occurred
Absolute reset not required
Battery voltage
*ALM OFF
Absolute reset
required
ON
OFF
*BALM signal
(PIO)
*ALM signal ON
OFF