8. Parameter
306
[76] Selection of pressing control (Parameter No.93)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
93 Selection of pressing control
FFRC
–
0: Current limit
1: Force sensor
In accordance with
actuator
This parameter defines the pressing method.
Set Value
Description
0
Pressing by current limit (when standard actuator)
1
Force sensor pressing (For the actuator with the
loadcell)
[Refer to 3.2.7 Pressing Operation Using Force Sensor Operation Ready.]
Use of loadcell
(Parameter No.92)
Selection of
pressing control
(this parameter)
Force sensor pressing
Pressing by current limit
(conventional method)
0: Does not use
1: Use
1: Force sensor
pressing
0: Pressing by
current limit
Selection of
pressing control
(this parameter)
Parameter error alarm
Pressing by current limit
(conventional method)
1: Force sencor
pressing
0: Pressing by
current limit