3. Operation
216
[2] Features of LS signals (LS0 to 2)
The LS* signals are not complete signals for positioning commands such as those for other PIO
patterns. Despite the specified position No., the corresponding LS* signal is turned ON when
the actuator is entered into the setup value range as if the actuator were detected by a sensor
installed.
(Example) The figure below shows the position table and the position at which each of the LS
signals is turned ON. If the actuator passes any of the positioning widths in the
operation by another position number or manual operation in the servo OFF state,
the relevant LS signal is always turned ON.
Caution: Even though a cold start error is generated, LS Signal would not turn OFF.
Home=0mm
70mm
150mm
LS0 is ON
0
±
5mm
LS1 is ON
70
±
10mm
LS2 is ON
150
±
5mm
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
0 0.00
250.00 0.20 0.20
0
0
5.00
0.00
0.00
0 0 0
0
1 70.00 250.00 0.20 0.20
0
0
10.00
0.00
0.00
0
0
0
0
2 150.00 250.00 0.20 0.20
0
0
5.00
0.00
0.00
0
0
0
0
3.2.6
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......