2. Wiring
114
3) Tighten the screw with
a slotted screwdriver
1) Loosen the screw
with a slotted screwdriver
2) Insert wire
BK+
PWR-
24V
0V
24V
0V
2.5.1.2 Brake Power Supply (Brake Power Supply Connector)
Supply 24V DC ±10% and 1A max. when using an actuator equipped with a brake.
● Wiring Image
● Wiring Method
Connect the power supply to the enclosed connector (Model code: MC1.5/2-ST-3.5: Phoenix
Contact).
See below for how to lay out the power supply wires.
1) Loosen the terminal screw with using such as a slotted screwdriver to open up the inlet.
2) Reveal the sheath for 7mm on the cable that satisfies the cable diameter complies the
specification shown in the table below and put it in the inlet.
3) Tighten the terminal screw with using such as a slotted screwdriver. The inlet closes and
affixes the wire.
4) Connect all the wires in the same manner and insert the enclosed connector to the power
connector.
Brake Power Supply Connector
Pin No.
Signal Name
Contents
Applicable cable diameter
BK+
24V DC power supply input
PWR-
24V DC ground
1.25 to 0.5mm
2
(AWG16 to 20)
24V DC power Supply
(
please prepare
separately
)
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......