2. Wiring
100
2.4 SCON-LC/LCG Type
2.4.1 Wiring Diagram (Connection of Construction Devices)
[1] Basic Wiring Diagram
Note 1 Please prepare separately.
If using RCS2-RA13R or NS Type for the actuator and the option shown in the table is applied, the
wiring between the actuator and the controller will differ from the basic wiring layout. Shown in the
table is the relation of the option and wiring layout.
○ : Equipped
× : Not Equipped
Option
Model Name
Brake
Loadcell
Wiring Layout between Actuator and Controller
○
×
1)
×
○
2)
○
○
3)
RCS2-RA13R
×
×
Basic Wiring Diagram
○
-
1)
NS
×
-
Basic Wiring Diagram
Caution: Make sure to turn the power to the controller OFF when inserting or removing the
connector that connects the PC software or touch panel teaching.
Inserting or removing the connector while the power is turned ON causes a controller
failure.
Power Supply for Brake
It is necessary when actuator with brake
Regenerative Resistor Unit
(REU-2 : option)
Required depending
on usage condition
[Refer to 1.5.3 Regenerative Unit]
LED Display
I/O Control
Power Supply
PLC
(e.g.) Relay)
(e.g.) Lamp)
(Note 1)
Load
(Note 1)
(Note 1)
Load
(Note 1)
(e.g.) Switch)
Load
(Note 1)
CB-SC-REU010
CB-ST-REU010
Power Source
Single Phase
100V AC or
200V AC
Regenerative Resistor Unit
(REU-1 [for secondary unit] : option)
Power
Supply
Connector
Flat Cable
(Accessories)
FG Connection
Terminal
Actuator
Teaching pendant (option)
PC Software (option)
(Note1)
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......