8. Parameter
317
[114] Total Movement Count Threshold
(Parameter No.147)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
147 Total Movement Count
Threshold
TMCT
Times
0 to 999999999
0(Disabled)
An alarm is generated when the total movement count exceeds the value set to this parameter.
The judgment would not be made if the value is set to 0.
[115] Total Operated Distance Threshold (Parameter No.148)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
148 Total Operated Distance
Threshold
ODOT
m
0 to 999999999
0(Disabled)
An alarm is generated when the total operation distance exceeds the value set to this
parameter.
The judgment would not be made if the value is set to 0.
[116] Zone Output Changeover (Parameter No.149)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
149 Zone Output Changeover
FPIO
0: Not to change
1: To change
0
When there is PZONE signal to the current PIO pattern or the Fieldbus Operation Mode and no
ZONE1 or ZONE2 signal, it is available to change the PZONE signal to either ZONE1 or
ZONE2 signal.
Caution:
x
ZONE1 signal is assigned prior to ZONE2 signal.
x
It would not function in the pulse train mode.
x
In the case there is no PZONE signal in PIO patterns, or both ZONE1
and ZONE2 signals exist, the setting would be invalid.
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......