3. Operation
244
3.3.5 Output Setting of Feeldback Pulse
This is a parameter to set when outputting the feedback pulse to the host controller (PLC, etc.).
This function is also available in Positioner Mode.
[1]
Setting Feedback Pulse Output Effective
Set it if the feedback pulse is to be used.
No.
Name
Symbol Unit Input
Range
Initial
Value
68
Feedback Pulse Output
FPIO
–
0 to 1
1
You can select whether to enable or disable the feedback pulse output.
0: Enable
1: Disable
Caution: Make this setting invalid if the feedback pulse is not output.