2. Wiring
127
2.5.7 Connectable Regenerative Units
Connect regenerative unit (s) with attached cables as shown in the figure below.
1) When connecting 1 unit
: Connect with enclosed cable (CB-SC-REU)
2) When connecting 2 or more units : Connect with enclosed cable (CB-ST-REU)
● Wiring Image
● Specification of connector for connecting external regenerative unit
Item
Items and Model
Connector Name
External Regenerative Unit Connector (RB)
Cable Side
1-178128-3
Controller Side
1-178138-5
Pin No.
Signal Name
Items
Applicable cable diameter
RB+
Regeneration Re
(Motor drive DC voltage)
RB-
Regeneration Resistor -
PE
Ground Terminal
Dedicated cable is enclosed
to regenerative unit
● [Reference number of connectable unit: Excluding RCS2-RA13R]
● [Reference number of connectable unit: RCS2-RA13R]
Motor Output
Connectable Number of Regenerative Units
to 100W
(Note)
Not Required
101 to 400W
1
Horizontal Mount/
Vertical Mount
401 to 750W
2
(Note) One unit is necessary for LSA/LSAS-N10S Types.
Motor Output
Connectable Number of Regenerative Units
Lead 1.25
Not Required
Horizontal Mount
Lead 2.5
1
Lead 1.25
1
Vertical Mount
Lead 2.5
1
RB IN
RB OUT
Regenerative Unit
Connector
1)
2)
REU-2
RESU-2
RESUD-2
REU-1
RESU-1
RESUD-1
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......