![IAI SCON-CB-F Instruction Manual Download Page 277](http://html1.mh-extra.com/html/iai/scon-cb-f/scon-cb-f_instruction-manual_604055277.webp)
5. V
ibration Suppress Control Function
261
Chapter 5 Vibration Suppress Control Function
The vibration suppress control function suppresses vibrations of loads induced by our
actuators.
The function can suppress vibrations in the same direction as the movement of the actuator in
the frequency range from 0.5Hz to 30Hz.
Measure the frequency of the generated vibration and set it to the parameter. Three
frequencies can be defined as parameters. Specify the parameters in the position table to
reflect them on suppression of vibrations generated by the operation. For a single moving
command (position data), only a single parameter can be set.
(Note) Before this function can be used, you must read the cautions described on the next
page.
[Functional Operation]
The figure below shows an example in which two actuators are subject to 2-axis combination.
Actuator A is moved to cause actuator B corresponding to a joint to be vibrated. Measure the
vibrations of B in the direction in which A is moved and make proper vibration suppress control
in the direction to suppress the vibrations of B. Vibrations of actuator B caused by the
movement of B cannot be suppressed.
A
A
B
(Joint)
B
(Joint)
Vibration in axis
moving direction
No setting of vibration suppress control
Setting of vibration suppress control
Summary of Contents for SCON-CB-F
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ......
Page 48: ...1 Specifications Check 32 1 3 3 SCON CGB 3000W and above ...
Page 60: ...1 Specifications Check 44 ...
Page 266: ...3 Operation 250 ...
Page 276: ...4 Field Network 260 ...
Page 282: ...5 Vibration Suppress Control Function 266 ...
Page 362: ...9 Troubleshooting 346 ...
Page 444: ...10 Appendix 428 ...
Page 449: ......