Fig. 54 Connecting rod alignment
1
Gas strut - cylinder
2
Ball cup
3
Connecting rod
4
Lubrication
3. Check both gas struts.
In order to ensure lubrication of the connecting rod, the connecting rod must be always
aligned towards the ground.
4. Check if both gas struts open the unlocked enclosure independently.
Enclosure opens independently until the technically possible opening angle.
5. Check if the already opened enclosure stays open.
Enclosure does not open properly or does not stay open.
➤ Replace both gas struts.
10.8 Check/replace hose lines
Overview of hose lines of machine:
■ Fuel lines of the drive engine
■ Pressure hoses of the drive engine
■ Pressure hoses of the compressor
The hose line are subject to natural ageing regardless of proper storage or permitted utilisa‐
tion during machine operation. This ageing changes the material and compound properties
and reduces the performance capability of the hose lines. As a result the period of use for
hose lines is limited.
The operator must ensure that all hose lines are checked at reasonable intervals and are re‐
placed if required, see maintenance schedule 10.2.3.1
➤ Comply with all instructions!
10.8.1 Replace the fuel lines of the drive engine.
➤ Have a KAESER SERVICE technician replace the fuel lines of the drive engine.
10 Maintenance
10.8 Check/replace hose lines
No.: 9_9548 22 HCE
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
143