Connections:
Voltage [V]
400 V, 3~
230 V, 1~
Power sockets
Number:
Number:
16 A; 400 V/3~/N/PE
1
−
16 A; 230 V/1~/N/PE
−
2
Tab. 48 Connection sockets
Circuit breaker
Voltage [V]
400/3~
230/1~
Safety cut-out [A]
Number:
Number:
16
1
1
Tab. 49 Circuit breaker
Maximum power loading by consumers:
Resistive consumers include incandescent electric lamps and heaters, for example.
Electric engines and transformers are inductive consumers.
Nominal rating conditions:
■ Ambient temperature: 25 °C
■ Max. height above sea level of the place of installation: 1000 m
Three-phase current:
Generator
400 V, 3~
Nominal power [kVA]
6.5
Resistive consumers [kVA]
6.0
Inductive consumers [kW]
4.0
Tab. 50 Maximum three-phase mains load
Alternating current:
Generator
230 V, 1~
Nominal power [kVA]
4.0
Resistive consumers
[kVA]
4.0
Inductive consumers [kW]
4.0
Tab. 51 Maximum AC mains load
2.8.3.2 115 V AC generator
The following connections are provided on the generator control cabinet:
■ 1 x 115 V AC (32 A)
■ 2 x 115 V AC (16 A)
2
Technical Specifications
2.8
Options
20
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
No.: 9_9548 22 HCE