Fig. 14 Minimum distance from excavations/slopes and walls
1. Keep sufficient distance (at least 1.5 m) from the edges of excavations and slopes.
2. Ensure that the machine is as level as possible.
The machine can be temporarily operated on a slope of not more than 5°.
3. Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
4.
NOTICE!
Danger of burning from build up of heat and hot exhaust.
Insufficient distance from a wall may well cause heat build-up that could damage the machine.
➤ Do not position the machine directly against a wall.
➤ Ensure always sufficient ventilation space around the machine.
5. Position the machine as far as possible from any wall.
6. Ensure there is enough free space all round and above the machine.
7. Keep air inlet and outlet openings free of obstructions so that the cooling air can flow freely
through the machine.
8. Place the machine in such a manner that
■ wind does not blow into the cooling air outlet.
■ exhaust gases and heated cooling air can not be drawn into the compressor.
5
Installation and Operating Conditions
5.2
Installation conditions
54
Operating Manual Portable Rotary Screw Compressor
MOBILAIR M27 PE
No.: 9_9548 22 HCE